Sterowniki i poradniki

Sterowniki

  • Wersja 2.1.3 Aktualna (5.1.2018) dla MK3 i MK2/S/MMU
    • Windows wersja 350 MB
    • Mac OSX wersja 500 MB
    • Instalacja Linux
      • Zobacz GitHub dla Linux AppImage builds.
      • Užyj Slic3r pakiet konfiguracyjny i obiekty próbki od Mac pakiet.
    • Version 2.1.3 changelog
      • MK3: Slic3r PE print settings without overextrusion and vastly improved cooling. Default infill chenged from cubic to grid.
      • MK3: 0.35mm FAST print settings removed as 0.20mm print setting already tops the E3D V6 flow rate of 15mm3/s
      • MK3: Sample objects updated with new print settings
      • MAC: To update the print profiles, copy the new Slic3r into Applications and run Configuration Assistant from the Help menu. Don’t forget to select „Reset user profile” to prevent mixing new and old settings.
    • Version 2.1.1 changelog
      • Slic3r Prusa Edition updated to version 1.38.6
      • MK3: Updated print settings with better print quality by reducing the infill perimeter overlap to 25%
      • MAC: Sample objects are updated to the latest revision
    • Version 2.1.0 changelog
      • Slic3r Prusa Edition updated to version 1.38.5
      • PrusaControl updated to version 0.9.4 which includes 32bit version
      • Updated MK3 print settings
      • MK2 MultiMaterial Single Mode print settings are moved to Multi Material Slic3r PE
      • Updated MK2 sample objects with LA to print faster
      • MK3 sample objects also updated
      • New sample objects are copied to folder with drivers version appendix – no need to backup anymore
      • MAC: Slic3r Prusa Edition has print settings baked in! Run it from Help -> Configuration Wizard
    • Version 2.0.0 changelog
      • Sample models and print settings for MK3 added
    • Version 1.9.2 changelog – Read more about this version at prusaprinters.org
      • Upto 10% faster print settings
      • Experimental Linear Advance print settings upto 30% faster
    • Version 1.9.1 changelog
      • Slic3r PE updated to 1.37.2
      • PrusaControl updated to 0.9.4_415_beta
      • Print settings update with Linear Advance
    • Lista zmian
  • Starsze wersje

Poradniki

  • Original Prusa i3 MK3
    • Angielski manual 7MB
    • – Wersja 3.1 (Mesh Bed Leveling, connecting Raspberry Pi Zero W, updated chapters about Power Panic, Spring steel sheets, Wizard…)
    • – 13. 12. 2017
    • Original Prusa i3 MK2 Multi Material
      • Angielski manual 3MB
      • – Wersja 1.0 (odpowiednia wersja początkowa, dodano ColorPrint MM, przetestowane filamenty, rozwiązywanie problemów …)
      • – 13. 10. 2017
    • Original Prusa i3 MK2S
      • Angielski manual 7MB
      • – Wersja 2.02 (update based on changes in firmware v3.1.0 – Linear Advance, SD Card sorting, etc.; Materials chapter update)
      • – 26. 11. 2017
    • Original Prusa i3 MK2
    • Original Prusa i3 „MK1” 1.75mm

      Manual odpowiedny dla 3mm wersji wyjątkiem materiału temperaturach i obrazów.

Pozostale

Firmware

Firmware 3.1.0 (12 listopada 2017)

MK1, MK2 i MK2 Multi Material są teraz obsługiwane.

prusa3d_fw_3_1_0.zip
Changes in 3.1.0 final:

  • Linear Advance
  • Wizard
  • Host keep alive messages – better OctoPrint compatibility
  • Sorting files in SD card menu by date or name
  • Check if file is complete
  • First layer calibration – V2 integrated into FW
  • Auto power mode
  • XYZ calibration details menu improved
  • PID calibration safety check
  • M220: Speed factor
  • Saving E steps per mm to EEPROM fixed
  • Long filename scrolling is improved

Read more about this major version at prusaprinters.org
There’s a known bug using Repetier server, please wait for the next release if you’re using it

 Lista zmian na Github

Firmware 3.1.1 RC4 b143 (30 grudnia 2017)

Tylko MK3.

prusa3d_fw_3_1_1_rc4_b143.zip

Changes in 3.1.1 b143 RC4:

  • Improved PowerPanic reliability on some printers
  • Filament unload function improved with smaller chance of blockage
  • Better OctoPrint reliability
  • Message warns user about disabling Crash Detection when switching from Normal to Stealth
  • AutoLoad is now more user friendly and smart, with better menus
  • Improved color changing “Color not clear” dialog
  • AutoLoading while cold now produces error message
  • Temperature calibration routine turns off the heatbed automatically at the end
  • Improved false MINTEMP detection

Changes in 3.1.1 b138 RC3:

  • Current in Z axis motor increased for better Z axis stability including better PowerPanic recovery
  • M110 command fixed
  • Temporarily disabled crash detections when printing via USB/serial
  • it was causing OctoPrint to hangup, we are working on a fix
  • Selftest now testing if filament sensor is properly connected and communicating
  • Setup function cleaned up for better readability
  • Better OctoPrint communication stability
  • Improved algorithm of filament autoloading
  • it won’t false trigger when filament is already loaded
  • Filament autoload can be turned off/on via LCD menu
  • Mintemp error masking by ambient temperature sensor reading improved for higher reliability
  • Main menu slightly reorganised
  • Wizard is now not asking if colour is clear when loading filament to prevent user confusion

Changes in 3.1.1 b137 RC2:

  • Fixed power panic routine when absolute possitioning of extruder is used
  • Random resets during Wizard caused by long user response time fixed, self test and PID calibration
  • Automatic Filament load during filament change
  • Incomplete file check implemented
  • Second serial line support implemented to allow Pi Zero W communication
  • Fail stats fixed (now resetable from Factory reset)
  • Fan test fixed (now possible to catch swaped fans)
  • Ambient temperature sensor conversion table fixed, and it’s used now to mask out MINTEMP error when printer is in low temperature environment
  • Stealth mode acceleration and maximum speeds are now limited to prevent layer shifts
  • Normal mode is now force set before XYZ calibration and self test
  • Crash detection menu setting during print fixed (sometimes turning it OFF/ON wasn’t working)
  • Filament sensor menu item now shows another state [N/A] which means the sensor is not attached, or not available because of possible wrong connection
  • File sorting in “Print from SD” implemented for up to 100 files per directory
  • Wizard tiggering during first run of printer fixed
  • Menu items properly masked during first layer calibration
  • Debuging output to serial line removed to prevent corrupting octoprint compatibility

Changes in 3.1.1 b122 RC1:

  • Initial MK3 release
  • Fixing XYZ calibration crashing from b121